| TYPE | PROTOCOL | DESCRIPTION | RESULTS |
|---|---|---|---|
| ENVIRONMENTAL PERFORMANCE | ASTM C518 | Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | K-Factor 0.138 BTU-in/hr-ft2-F0 at 75° mean K-Factor 0.130 BTU-in/hr-ft2-F0 at 35° mean |
| ASTM E283 | Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen | 0.0011-cfm/sf at 20-psf | |
| ASTM E331 | Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference | Zero penetration at 20-psf | |
| FOAM CORE CHARACTERISTICS | ASTM C273 | Shear Properties of Sandwich Core Materials | Shear Strength = 16-psf |
| ASTM D1621 | Compressive Properties of Rigid Cellular Plastics | Compressive Strength – 18-psf | |
| ASTM D1622 | Apparent Density of Rigid Cellular Plastics | Apparent Density – 2.50-pcf Nominal | |
| ASTM Dl623 | Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics | Tensile Strength – 21-psf | |
| FIRE RESISTANCE | ASTM E84 | Surface Burning Characteristics of Building Materials | Flame Spread < 10, Smoke Developed < 85 |
| NFPA 285 | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components | Passed – see Intertek listing Intertek.com | |
| FM 4880 | Factory Mutual Approval Standard for Class l Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems | Passed (Factory Mutual website) | |
| NFPA 286 | Standard Fire test for internal walls and ceiling | Passed | |
| IMPACT RESISTANCE | TAS 201 | Florida Building Code Impact Test Procedure | Passed |
| ENGINEERING PROPERTIES | FM 4881 | Factory Mutual Approval Standard for Class l Exterior Wall Systems | Passed See Load Charts ( Factor Mutual website) |
| ASTM E1592 | Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference | See Load Tables | |
| ASTM E72 | Strength Tests of Panels for Building Construction | See Load Tables | |
| APPROVALS | FM 4882 | Factory Mutual approval for Clean Rooms | Approved |
| State of Florida | Florida Product Approval | Approved # FL47552 | |
| IAS | International Association of Steel Buildings | Accredited AC-473 |